Fasco 誘導ドラフト炉ブロワー | Raptor Supplies 日本

FASCO 誘導ドラフト炉ブロワー


Fasco induced draft furnace blowers are used in heating systems to improve combustion efficiency by facilitating the removal of combustion gases. Positioned after the heat exchanger, they create a negative pressure, ensuring the proper venting of flue gases, enhanced safety, energy efficiency a...nd overall furnace performance.続きを见る

フィルタ
備考: 直接OEM交換としてのみ使用される製品。 その他の使用は誤用を構成し、保証が無効になり、危険な状態が発生する可能性があります 、 タイプ: 交換
形式モデル電圧アンプ深さ出力幅(Width)ブランドに合う製造元で使用するため。 モデル番号高さ価格
A
A086
1151.36-3 / 8」1189"リーム7030207.875 "¥83,189
B
A157
1151.35-3 / 4」719"グッドマンB18590058.875 "¥54,370
C
A079
1151.15-7 / 8」908.625 "グッドマン、トレーンB1859000, 7021-6804, B1W24, WG94X1677.5 "¥57,334
D
A129
1151.957"1558.38 "アマナ11009001、117521-007.5 "¥103,202
E
A131
1151.15-7 / 8」838.75 "ノルダイン62128507.75 "¥70,091
F
A130
1150.75-5 / 8」739"トレーンD330757P039.5 "¥109,582
G
A134
1151.56-3 / 4」12410.62 "ICP1708-6078.5 "¥63,152
H
A140
1151.46-3 / 8」1079"グッドマンB28330019.875 "¥72,097
I
A143
1150.9506"918.625 "トレーンD330673P017.5 "¥59,451
J
A146
1151.0 / .356"738.625 "トレーン21D340096P047.5 "¥111,772
K
A142
1150.76-3 / 8」859.125 "リーム70-22165-817.75 "¥135,203
L
A064
1150.6505-7 / 8」678.625 "ハイルクエーカー610172, 7021-5043, 7021-71027.5 "¥53,445
M
A088
1151.36-1 / 2」939"Evcon / York2940-3917.875 "¥88,355
N
A090
1151.15-7 / 8」908.625 "リーム70-21496-017.5 "¥68,216
O
A150
208/2300.5006"818.75 "トレーンC661452P017.75 "¥68,813

動作メカニズム

  • The furnace initiates the heating process by igniting fuel, generating a heat source.
  • Subsequently, the heat exchanger efficiently warms the circulating air.
  • As the Fasco blower comes into action, it establishes a negative pressure.
  • This negative pressure facilitates the removal of combustion gases induced by the combustion process.
  • Ensuring safety, these expelled gases are effectively vented out.
  • This entire mechanism collectively contributes to enhanced combustion efficiency, ultimately delivering optimal heating performance.

特徴

  • They feature a wheel-type forward-curved design for efficient air movement.
  • These blowers utilise polypropylene wheels for durability and corrosion resistance.
  • They are equipped with a shaded pole motor type for reliable performance.
  • These blowers have an electrical connection with wire leads for convenient installation and connectivity.

よくある質問

What safety precautions should I take while using these draft furnace blowers?

  • Always turn off power before maintenance.
  • Allow the blower to cool before touching.
  • Use appropriate safety gear (gloves, eyewear).
  • Adhere to manufacturer's safety instructions.
  • 複雑な問題については専門家の支援を求めてください。
  • Ensure proper ventilation during maintenance.
  • Periodically inspect for wear or damage.

How do I clean and maintain Fasco induced draft furnace blowers?

  • 炉の電源を切ります。
  • Remove the access panel to reach the blower.
  • Gently clean dust and debris from the blower blades.
  • Check and tighten belts if necessary.
  • Ensure the furnace filter is clean, replace it if needed.
  • Schedule periodic professional inspections for optimal performance.

What factors should I consider while choosing a draft furnace blower?

  • Ensure compatibility with your furnace model.
  • Choose a size and capacity that matches your furnace.
  • Opt for high energy efficiency to reduce costs.
  • Consider noise level for a quieter system.
  • Prioritise durability with quality materials.
  • Select ease of installation and fit for your furnace configuration.

私たちは助けに来ています!

ここに記載されていない部品をお探しですか?